A femalemale coupling made of expanded polypropylene
(EPP) is used to connect the EPP15 ducts, when the male part
is cut off (e.g. when duct is shortened). The female coupling
fits the outer diameter of the 15 mm duct. The couplings are
produced in 125, 160 and 200 mm sizes.
Thermal conductivity 0.039 W / m*K
Airtightness class ATC2 (old D) @ 90 Pa acc. to PNEN 17192201901
Our conventional and CNC machining include turning services – lathe machining that is suited for producing wooden as well as steel, iron and aluminum components. We also offer plywood turning.
Stojak na butle gazowe VGCB12 to solidne i niezawodne rozwiązanie zaprojektowane z myślą o bezpiecznym przechowywaniu i transporcie butli gazowych. Wykonany z wytrzymałej stali, stojak jest odpowiedni do użytku z dźwigami i wózkami widłowymi, co czyni go niezwykle wszechstronnym narzędziem w codziennej pracy. Dzięki obróbce powierzchniowej w postaci malowania proszkowego RAL, stojak jest odporny na korozję i uszkodzenia mechaniczne, co zwiększa jego żywotność.
Stojak na butle gazowe VGCB12 jest łatwy w montażu i demontażu, co czyni go niezwykle praktycznym narzędziem w dynamicznych środowiskach pracy. Dzięki kompaktowym wymiarom i niskiej wadze, stojak jest łatwy w przemieszczaniu, co jest szczególnie przydatne w miejscach o ograniczonej przestrzeni. VGCB12 to doskonałe rozwiązanie dla firm poszukujących niezawodnego i funkcjonalnego sprzętu do przechowywania butli gazowych.
Imitation natural leather, otherwise artificial leather produced by us on a PVC basis. Stock replenished on an ongoing basis. An upholstery material of excellent strength and resistance. Wide range of colours. Used as an upholstery material. Model favoured by companies producing fashionable sack-type seats filled with polystyrene balls (sako bag / bean bag) and dog beds for both homes and cars.
As a manufacturer, we can match the colour and technical specification to our customers' requirements.
Rolka: ok. 40 mb
Waga brutto rolki:30 kg
Standardowa szerokość:145 cm
Minimalna ilość zamówienia:1 roll
Maksymalna szerokość - opcja:152 cm
Minimalna ilość zamówienia:400 - 500 lm
Grubość:0,75 (+/- 0,05) mm
Female coupling made of expended polypropylene (EPP)
for connecting 43 mm thick ducts. The coupling is used as
additional piece, for example when connecting ducts which
were cut. Such coupling is put on the outer diameter of a duct.
The female couplings are produced in the following diameters
125, 160 or 200 mm.
Thermal conductivity 0.039 W / m*K
Airtightness class ATC2 (old D) @ 110 Pa acc. to PNEN 17192201901
Our conventional and CNC milling and machining services can be utilized for producing wooden components according to customer's design and requirements.
ILA maleend flexible duct connectors are used for joining
two round SPIRAL or plain ducts. They are most often used
for connecting air handling units, heat recuperation units, and
duct fans. The flexible duct connector deadens the vibration
generated by the equipment to prevent vibration and noise in
the ductwork and ensure improved acoustic performance of
the ventilation system. The flexible piece is made from AMT
balancing tape, a standalone product available in different
sizes and materials, including a heatresistant version.
The standard version is male.
The femaleended version is available on request for connecting
two fittings.
Round plastic ventilation pipes are joined by welding (or PVC
gluing up to ø250). Manufactured in accordance with DIN
8062 standards for ventilation pipes. PVC pipes of larger
diameter than 500mm are made of sheets. Pipes made of
PP, PPs, PE and PPELs are extruded. Other wall thicknesses
are available on request.
Round ventilation duct made of expanded polypropylene
(EPP). The most important features of the product are
rigid construction, low weight, easy assembly (integrated
malefemale coupling) and good thermal insulation. EPP
ducts, used, for example, as sections of the supply and
exhaust ventilation systems with heat recovery, do not require
additional insulation. The system eliminates the formation of
thermal bridges.
Lenght EPP ducts 1 m sections
Diameters 125, 160 and 200 mm.
Wall thickness 15 mm
Thermal conductivity 0.039 W / m*K
Airtightness class ATC2 (old D) @ 90Pa
acc. to PNEN 17192201901
The silencers are delivered with the SPIRAL®
system seals in
the standard version. The diameter sizes d1 > 315 mm require
ordering the NSL male couplings which need to be installed in
the silencer before connecting the silencer to the ductwork. The
male fittings are available separately. They are not delivered
with the silencers. Glass wool thickness inside the silencer
50 mm for SIL50 depends on the outer cladding size.
100 mm for SIL100 depends on the outer cladding size.
Insulation
Insulation material glass wool.
Insulation type trimmed from reel, flexible.
Reaction to fire A1 acc. to EN 13162
The fire dampers are manufactured in the following nominal
sizes DN100, DN125, DN160, DN200. The fire dampers are
equipped with a thermal fuse mechanism ensuring the damper
switch to the safe position in case of reaching an ambient
temperature equal to or higher than 72°C. The fire dampers
allow using limit switches signalling closed position of the
damper blade (1 limit switch) or blades (in case of using
2 limit switches).
The casing is made from galvanised steel sheet; the fire damper
blade is made from a silicate cement board.
Stojak na butle gazowe VCCS dla 8 lub 12 cylindrów to zaawansowane narzędzie zaprojektowane z myślą o bezpiecznym przechowywaniu i transporcie butli gazowych. Wykonany z wytrzymałej stali, stojak jest odpowiedni do użytku z dźwigami i wózkami widłowymi, co czyni go niezwykle wszechstronnym narzędziem w codziennej pracy. Dzięki obróbce powierzchniowej w postaci malowania proszkowego RAL, stojak jest odporny na korozję i uszkodzenia mechaniczne, co zwiększa jego żywotność.
Stojak na butle gazowe VCCS jest łatwy w montażu i demontażu, co czyni go niezwykle praktycznym narzędziem w dynamicznych środowiskach pracy. Dzięki kompaktowym wymiarom i niskiej wadze, stojak jest łatwy w przemieszczaniu, co jest szczególnie przydatne w miejscach o ograniczonej przestrzeni. VCCS to doskonałe rozwiązanie dla firm poszukujących niezawodnego i funkcjonalnego sprzętu do przechowywania butli gazowych.
The FDA212 round fire dampers are designed for use in
general ventilation systems to seal off smoke and fire between
adjacent fire partitions.
The fire dampers are classified according to EN 135013+A12010P
(Fire classification of construction products and building
elements). The fire resistance was tested as per PNEN 1366
22015 (Fire resistance tests for service installations — Part 2
Fire dampers). The entire manufacturing process meets the
requirements of EN 156502010.
The FDA212 fire dampers can be installed in horizontal and
vertical fire partitions to provide fire resistance of EI 120
(ve ho i↔o) S (which may depend on the actual fire resistance
of the partition).
The fire dampers are available in the nominal diameter sizes
DN200, DN224, DN250, DN280, DN300, DN315, DN355,
DN400, DN450, DN500, DN560, DN600, DN630. All fire
dampers have a torsion spring trip (in FDA212T) or a returnspring actuator coupled with a thermal trip (in FDA212M).
Plug ends are pressed with a male end on the duct
side to blind it at air tightness class D. The plug end
rim is long enough to easily secure it with WGO screws
without any risk of cutting the gasket's double lip.
CPSL plug ends are equipped with a stop fold
which prevents inserting the fitting too deep
into the duct.
Safe edges (rolled edges) allow the duct
installer safer installation of the ductwork, by
minimizing the possibility of cuts.
FLXPLO / FLXPRO plenum boxes are components of the FLXREKU system intended for domestic mechanical ventilation
systems, also known as mechanical ventilation heat recovery
(MVHR) or heat recovery ventilation.
The low profile plenum boxes require less installation space
than standard solutions, which is very convenient when they
should not be prominent once concealed. This advantage
helps free up usable indoor area.
FLXPLO plenum boxes are made of galvanized steel sheet.
Plenum boxes made from stainless steel are available on
request.
Available also insulated plenum box version FLXPLI and
FLXPRI. These plenum boxes have inside a insulation lining
made from 9 mm thick rubber foam.
FLXPLO plenum boxes are equipped with duct connection
spigot Ød2 with a EPDM seal – this type of connection with
FLXHDPE ducting is airtight and easy to install.
longitudinal welding with overlap pipe for transporting air and
dust. TRANSQuick system is made of galvanised steel sheet, 0.7
and 0.9 mm in thickness. Depending on the wall thickness there
are available various lengths
0.7 mm thickness L=500 / 1000 / 1480 mm.
0.9 mm thickness L=500 / 1000 mm
The FDA212 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification of construction products and building elements). The fire resistance was tested as per PNEN 1366 22015 (Fire resistance tests for service installations — Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA212 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN200, DN224, DN250, DN280, DN300, DN315, DN355, DN400, DN450, DN500, DN560, DN600, DN630.
The HRUSlimAIR heat recovery unit is designed for
residential buildings. The HRU has a capacity of 250 m3/h
@ 100 Pa, generated by energyefficient EC fans. Thanks
to a counterflow heat exchanger made of a plastic (PET), it
achieves up to 90% heat recovery An ERV version with an
enthalpy exchanger that recovers moisture is also available.
Builtin electric preheater protects heat exchanger against
freezing, wireless radio communication connects controllers
and sensors, and all of it is enclosed inside a selfsupporting,
insulating EPP casing.
HRUSlimAIR can be installed in up to 3 positions, thanks to
a special condensate drain system.
Round spiral ducts are available in diameters from 80 mm to
1600 mm. The ducts are available as made of 0.4 mm to 1.8
mm thick metal sheet; the ducts in diameters of DN 160 mm
or greater are also available with corrugation for improved
stiffness and vacuum strength. The corrugations are available
as a standard feature for diameters of DN 250 mm to DN
1600 mm. All spiral ducts made from galvanized steel sheet,
stainless steel sheet or aluminium sheet meet requirements
of air tightness class D according to EN 12237.
material:galvanized steel sheet
diameters:80-1600mm
airtightness:class D
sheet thickness:0.4 to 1.8 mm
HHS wall diffuser for fresh air supply. Male connector with
gasket for fast connection with SPIRAL® duct. Powder painted
with white RAL 9010 colour which provides additional
protection from corrosion in places with high humidity, such
as bathrooms.
An excellent choice when celling mounting is out of the scope
or the interior design requires a wall diffuser. It can be used
in offices, residential houses and mounted just under the
ceiling as well.
The smog filter is designed for effective filtration of the
socalled particulate matter. The PM2.5 and PM10 particles are
the main component of smog, which have an optical diameter
of 2.5 and 10 μm (micrometers). The filtration efficiency
(removal) of PM2.5 particles reaches up to 73%, and PM10
particles up to 81% (according to tests carried out with a dust
particle measuring device). The smog duct filter consists of
a sealed filter box and two filters prefilter and smog filter.
It is recommended to install a smog filter on the supply ducts
in domestic ventilation and heat recovery systems.
In the MOCarzCA version prefilter I3 was replaced by an
activated carbon prefilter (or activated charcoal). The main
purpose of using such a material is deodorization of air and
preliminary cleaning of dust and gaseous pollutants. Activated
carbon has a huge adsorption surface, which effectively "binds"
on its surface particles of pollutants, bacteria, hydrocarbons.
The FDA12 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification f construction products and building elements). The fire resistance was tested as per PNEN 136622001P (Fire resistance tests for service installations Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA12 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN100, DN125, DN160, DN200, DN250, and DN315. All fire dampers have a pull spring control gear and a fusible thermal trip (in FDA12T) or a returnspring actuator coupled with a thermal trip (in FDA12M).
Ventilation bends 45˚ made from expanded polypropylene
(EPP). Bends are produced in diameters 125, 160 and 200 mm.
The standard wall thickness is 43mm (black colour). The
connection method eliminates thermal bridges, no additional
couplings are required.
To create a 90° bend two 45° beds can be connected together.
Thermal conductivity 0.039 W / m*K
Airtightness class ATC2 (old D) @ 110 Pa acc. to PNEN 17192201901
The DAOS dampers feature a split flap closure and allow the
air flow to pass in one direction only. The aluminium closure
flaps are pressed against a foam seal when closed to reduce
the operating noise in the ductwork. The split flap closure is
held closed with a spring gear, which makes it also possible
to use the damper in vertical installations. A version intended
for a fullmale insertion into the ductwork ends is available
on special request.
WKLDB cantilever support arms are designed for installing
rectangular ventilation ducts directly along walls and for
supporting heavy HVAC components, including A/C split indoor
and outdoor units and AHUs. The additional bracing enhances
the load capacity, permitting a wider clearance between the
suspended installation parts and the walls
FLXHDPE and FLXHDPEA plastic ducts are used to air
distribution in domestic ventilation systems. Relatively small
diameters allow to hide the installation in ceilings, screeds
or suspended ceilings. FLXHDPE and FLXHDPEA semirigid ducts are connected to other system components like
plenum boxes or distribution boxes with a simple push fit
connection. Application of seals on the FLXPLO plenum
boxes’ spigots guarantees high air tightness system.
FL XHDPE and FL XHDPEA semirigid ducting is
made of highimpact polyethylene. This makes the
entire ventilation ductwork very durable.
FLXHDPEA ducts are complying with European norm
EN 171922018 for rigid or semirigid nonmetallic
ductwork, which defines the test methods and performance
characteristics like airtightness, pressure drop, reaction to
fire, resistance to external pressure , thermal resistance and
microbial resistance.
FLXHDPE75 semirigid ducts without an
antibacterial coating are gray.
Heat recovery ventilation unit HRUPremAIR is a modern
device with 350 / 450 or 500 m3/h air flow @ 100 Pa. Unit
is made from cutting edge materials aluminim heat
exchanger and EPP selfsupporting casing. Depending on
the model, following heat exchangers are used counterflow
aluminium heat exchanger (HRV) or counterflow enthalpy
exchanger (ERV).
Enthalpy exchangers in HRUPremAIRE series have a polymer
membrane that effectively recovers heat and moisture from
the extract air. Such membrane works like a membrane in
waterproof trekking clothing i.e. it allows water vapour to pass
through, but not liquid water and air. The enthalpy exchanger
also blocks the transfer of odours, bacteria and spores.
The exchanger material, is needless to say, primarily optimized
for maximum heat recovery efficiency.
PremAIR air handling units optionally can be equipped
with the Constant Flow system, whose task is to maintain a
constant air flow in the installation.
The RACAV constant air velocity regulator keeps the air output
steady in ventilation systems. The device works without
any electric power supply and from the minimum pressure
differential shown in Chart 1 to the maximum pressure
differential of 1000 Pa. The air velocity stability may be
reduced outside the range shown in the differential pressure
chart. The regulator can be used in comfort or industrial air
supply and air exhaust systems.
GCR swirl diffuser is equipped with fixed blades bent
at a constant angle. It is made of galvanized steel sheet,
powder coated in RAL9010. Swirl diffusers ensure
mixing of the fresh air stream with the room air, which
is recommended for supplying cold air. They provide
a stable flow of the stream and are intended
for rooms up to 4m high, for example in public
facilities such as hotels, restaurants, office buildings.
The perforated plate leads to rapid
air flow velocity decrease at low noise
levels.